HPS dVdT Filter Research Accepted in IEEE

February 8, 2024

HPS dVdT Filter Research Accepted in IEEE

“Comprehensive Study of DVDT Filter for Motor Drive System with Long Cable Lead,” published at the Institute of Electrical and Electronics Engineers (IEEE)

Haider Razak, HPS Principal Engineer in Power Quality and Power Conversion Solutions, alongside Manish Saraf, VP Design Engineering have had their paper, “Comprehensive Study of DVDT Filter for Motor Drive System with Long Cable Lead,” published at the Institute of Electrical and Electronics Engineers (IEEE) Energy Conversion Conference and Expo (ECCE). This research addresses the significant challenges faced by motor drive systems in industrial applications with long cable leads.

The comprehensive study delves into the nuanced issues associated with motor drive systems operating in environments with extended cable leads. The article not only identifies the challenges faced by motor drive systems but also provides a practical solution that can be implemented across various industrial applications. The authors have examined the performance under different operating conditions and system parameters such as motor loading, motor speed, cable length, cable size, cable type, switching frequency, and the mode of operation. The findings have the potential to enhance the efficiency, reliability, and cost-effectiveness of motor drive systems operating with long cable leads.

See the paper abstract and link to the IEEE website below.

Abstract:

This paper provides an in-depth analysis of the issues and challenges of motor drive systems in industrial application with long cable lead. Moreover, it presents a simple and economical filtering solution to these challenges under different system parameters and operating conditions. The system parameters include cable length, cable size, cable type, and drive system size. The operating conditions include switching frequency, output operating frequency, and loading condition. The motor peak voltage, which is the main concern in such applications, is investigated along with the power dissipation of the filter.

Testing with three motor drive systems (10, 25 and 100HP) with different cable lengths (500-1500ft), different cable sizes (#8, #2, 4/O), and different cable types (VFD, TECK) are used to experimentally validate the design and analysis of this paper.

Read the full paper on the IEEE website

Source

Related Product

New Hammond Power Solutions Centurion D1 dVdT Filter

Hammond Power Solutions (HPS) has a new addition to their line of power quality products – HPS Centurion D1 dVdT Filter. The HPS Centurion D1 is designed for use between variable frequency drives (VFD’s) and motors when long lead lengths are used. It combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.

These filters provide protection for both the motor and cables that power it, and are typically used when the cable length exceeds a value that can lead to high voltage levels caused by reflected wave phenomena. dVdT filters provide protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and terminals.

Related Articles



Editor’s Pick: Featured Article

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s scalable engineering software, u-control 2000, adapts individually to your requirements. And, the u-control is powerful, compact and fully compatible with Weidmüller’s I/O system u-remote. This article looks at what makes u-control the heart of your automation.

Programmable logic controllers (PLCs) are one of the main components of any automated system. A typical control system has inputs, outputs, controllers (i.e., PLCs), and some type of human interaction with the system, a human machine interface (HMI), for example.

Read More



Latest Articles

  • SmartD’s Innovation in VFD Filters: Transforming Complex System Laden with Challenges into Efficient Solutions

    May 8, 2024 In a recent blog post, SmartD delved into the challenges associated with the introduction of Variable Frequency Drives (VFDs) into electrical systems. As a brief reminder, these challenges stem from the Pulse Width Modulation (PWM), a fundamental aspect of VFD functionality. This waveform introduces complications such as voltage spikes, corona discharge, common… Read More…

  • Improving Industrial Sensing: Omron’s Smart Fiber Sensor

    May 7, 2024 In today’s fast-paced industrial landscape, efficiency and reliability are paramount. Manufacturers are constantly seeking innovative solutions to optimize their processes and minimize downtime. Omron, a leader in industrial automation, has recently unveiled its latest Fiber Optic Amplifier which addresses critical market problems, and improves the way industrial sensing is approached. This blog… Read More…